ACR PLB Battery Replacement #1103 - (LiMnO2) ResQLink Class 2, (PLB-375) Non Hazmat BRC Only
Description
Authorized Battery Replacement
The ACR 1103 battery is installed as part of a professional service rather than sold for owner installation. ACR specifies that PLB battery replacement should be completed by a certified technician or authorized service center to ensure the beacon is properly serviced and tested afterward.
ResQLink Model Compatibility
This service is intended for the PLB-375 beacon platform, including:
- ACR ResQLink, product number 2880
- ACR ResQLink+, product number 2881
Additional product-number variants beginning with the same four digits may use the same PLB-375 documentation, but the model and existing battery markings should be confirmed before service.
Replacement Schedule
The battery is due for replacement six years from its manufacturing date or five years after the beacon is placed into service, whichever occurs first. It must also be replaced after the PLB has been activated during an emergency. The expiration label on the individual beacon should be checked before arranging service.
Emergency Operating Capacity
The replacement battery supports the PLB-375’s Class 2 operating requirements. ACR specifies more than 24 hours of operation at -4°F (-20°C), with typical beacon performance listed at approximately 30 hours under test conditions.
Inspection and Testing
The Battery Replacement Center services the complete beacon rather than simply supplying replacement cells. This allows the PLB to be resealed and functionally tested before it is returned for continued use. Any damage or faults discovered during inspection may require additional repair work.
Shipping the Beacon
The PLB-375 uses a Class 2 non-hazmat lithium battery configuration. The installed battery system has passed applicable UN 38.3 transportation testing, but carrier requirements and lithium-battery documentation may still apply. The selected service center should provide shipping instructions before the beacon is sent.
Technical Specifications
Included
- Replacement ACR 1103 LiMnO₂ battery system
- Opening and resealing of the compatible PLB
- Post-replacement beacon inspection
- Functional testing
- Updated battery service or expiration marking
- Return of the serviced beacon
Battery
- Battery chemistry: Lithium manganese dioxide (LiMnO₂)
- Battery classification: Class 2, non-hazmat
- Operational life: More than 24 hours at -4°F (-20°C)
- Typical operational performance: Approximately 30 hours
- Replacement interval: Six years from manufacture or five years after being placed into service, whichever comes first
- Replacement also required after emergency use
- Battery storage temperature: -40°F to 158°F (-40°C to 70°C)
Additional
- Service part number: 1103
- Compatible beacon model: PLB-375
- Compatible with ACR ResQLink, product number 2880
- Compatible with ACR ResQLink+, product number 2881
- Authorized Battery Replacement Center service only
- Battery is not intended for customer installation
- Beacon model, serial information, manufacture date, and expiration marking should be confirmed before service