Hughes 9410 Power & Data Cable – Blunt Wire, 5 m
Description
Combined Power and Data Connection
The cable connects to the single power-and-Ethernet port on the Hughes 9410 terminal. It carries 12V DC power, ground, remote ignition sensing, and Ethernet signals, reducing the number of separate cables required between the terminal and equipment inside the vehicle.
Blunt-Wire Installation
The unterminated end exposes color-coded conductors for connection to a compatible power source and Ethernet interface:
- Red: 12V DC power
- Black: Ground
- White: Remote switch or ignition sense
- Green and white/green: Ethernet receive
- Orange and white/orange: Ethernet transmit
- Yellow: Not used
This configuration allows the cable to be integrated into a vehicle fuse panel, power-distribution system, or custom networking setup by an authorized installer.
Ethernet Termination
The exposed Ethernet conductors can be connected to the optional Hughes RJ45 Wiring Block, part number 9510250-0002. Hughes specifies a straight-through wiring arrangement when terminating the cable to an RJ45 network connection.
Compact Vehicle Installations
The 5 m cable is suitable for utility vehicles, emergency response units, fleet vehicles, and mobile work platforms where the power and networking equipment are installed close to the roof-mounted terminal. The shorter length reduces excess cable compared with the 10 m version while retaining the same power-and-data functions.
The terminal requires a 12V DC source. Hughes specifies a 10A fuse at the power source and a circuit capable of supplying at least 6A.
Technical Specifications
Power
- Input voltage: 12V DC
- Power conductor: Red
- Ground conductor: Black
- Remote switch/ignition-sense conductor: White
- Required source fuse: 10A
- Minimum available circuit current: 6A
Dimensions
- Cable length: 5 m / 16.4 ft.
Included
- Hughes 9410 Power & Data Cable – Blunt Wire, 5 m
Additional
- Compatible terminals: Hughes 9410L and 9410LW
- Installation type: Permanent hardwired installation
Data Network
- Network type: Ethernet
- Ethernet wiring: Two transmit and two receive conductors
- Wiring configuration: Straight-through
- Optional RJ45 wiring block: Hughes 9510250-0002
Interfaces
- Terminal end: Hughes 9410 combined power-and-data connector
- Installation end: Blunt wire
- Functions carried: DC power, ground, ignition sensing, and Ethernet